<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href="http://www.blogger.com/styles/atom.css" type="text/css"?><feed xmlns='http://www.w3.org/2005/Atom' xmlns:openSearch='http://a9.com/-/spec/opensearchrss/1.0/' xmlns:georss='http://www.georss.org/georss' xmlns:gd='http://schemas.google.com/g/2005' xmlns:thr='http://purl.org/syndication/thread/1.0'><id>tag:blogger.com,1999:blog-5516642498532545789</id><updated>2012-02-15T22:52:05.307-08:00</updated><title type='text'>MRI MACHINES</title><subtitle type='html'>mri machines latest product, mri machine review, mri machine equipment, mri machine function, mri machine manufacturer, mri machine technology</subtitle><link rel='http://schemas.google.com/g/2005#feed' type='application/atom+xml' href='http://mri-machine.blogspot.com/feeds/posts/default'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5516642498532545789/posts/default?max-results=100'/><link rel='alternate' type='text/html' href='http://mri-machine.blogspot.com/'/><link rel='hub' href='http://pubsubhubbub.appspot.com/'/><author><name>faku</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author><generator version='7.00' uri='http://www.blogger.com'>Blogger</generator><openSearch:totalResults>1</openSearch:totalResults><openSearch:startIndex>1</openSearch:startIndex><openSearch:itemsPerPage>100</openSearch:itemsPerPage><entry><id>tag:blogger.com,1999:blog-5516642498532545789.post-2792233684798411094</id><published>2008-05-03T09:46:00.000-07:00</published><updated>2008-06-14T07:04:14.958-07:00</updated><title type='text'>M R I (Magnetic Resonance Imaging) : MAGNETOM Verio 3T</title><content type='html'>&lt;span style="font-family:verdana;"&gt;MRI (Magnetic Resonance Imaging) provides detailed images of the body in any plane. MRI technique primarily used in Radiology to visualize the structure and function of the body. MRI especially useful in neurological, musculoskeletal, cardiovascular, and oncological imaging.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:verdana;"&gt;MRI uses no ionizing radiosation, but uses a powerful magnetic field to align the nuclear magnetization of (usually) hydrogen atoms in water in the body. Radiofrequency fields are used to systematically alter the alignment of this magnetization, causing the hydrogen nuclei to produce a rotating magnetic field detectable by the scanner. This signal can be manipulated by additional magnetic fields to build up enough information to reconstruct an image of the body.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="color: rgb(153, 0, 0);font-family:verdana;" &gt;&lt;br /&gt;MRI MACHINE : MAGNETOM Verio 3T&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;a style="font-family: verdana;" onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://bp3.blogger.com/_-px19S2_2wM/SBzPg_VaC4I/AAAAAAAAAB4/NXf9wXblE8s/s1600-h/MRI+MAGNETUM+VERIO+T3.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 300px; height: 200px;" src="http://bp3.blogger.com/_-px19S2_2wM/SBzPg_VaC4I/AAAAAAAAAB4/NXf9wXblE8s/s400/MRI+MAGNETUM+VERIO+T3.jpg" alt="" id="BLOGGER_PHOTO_ID_5196256235742694274" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span class="fullpost"&gt;&lt;br /&gt;&lt;span style="font-family:verdana;"&gt;The following information will provide you with more technical details about MRI : &lt;/span&gt;&lt;a style="font-family: verdana;" href="http://www.medical.siemens.com/webapp/wcs/stores/servlet/CategoryDisplay%7Eq_catalogId%7Ee_-11%7Ea_categoryId%7Ee_12754%7Ea_catTree%7Ee_100010,1007660,12754%7Ea_langId%7Ee_-11%7Ea_storeId%7Ee_10001.htm"&gt;&lt;span style="color: rgb(0, 51, 51);"&gt;MAGNETOM Verio 3T.&lt;/span&gt;&lt;br /&gt;&lt;/a&gt;&lt;ul  style="font-family:verdana;"&gt;&lt;li&gt;&lt;span style="color: rgb(153, 51, 153); font-weight: bold;"&gt;70 cm Open Bore design&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;span style="font-family:verdana;"&gt;Unique 70 cm CT-like patient bore diameter accommodates 36% more patient volume, Table accommodates up to 250 kg or 550 lbs patients&lt;/span&gt;&lt;br /&gt;&lt;ul  style="font-family:verdana;"&gt;&lt;li&gt;&lt;span style="color: rgb(153, 51, 153); font-weight: bold;"&gt;Tim&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;span style="font-family:verdana;"&gt;Up to 102 seamlessly integrated coil elements with up to 32 RF channels, Up to 50 cm FoV. Whole Body imaging functionality up to 196 cm, iPAT2. Unmatched PAT up to 16.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;a style="font-family: verdana;" onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://bp0.blogger.com/_-px19S2_2wM/SBzPrPVaC5I/AAAAAAAAACA/PTCr5214zM0/s1600-h/MRI+MAGNETUM+VERIO+3T.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer;" src="http://bp0.blogger.com/_-px19S2_2wM/SBzPrPVaC5I/AAAAAAAAACA/PTCr5214zM0/s400/MRI+MAGNETUM+VERIO+3T.jpg" alt="" id="BLOGGER_PHOTO_ID_5196256411836353426" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;ul style="font-weight: bold; font-family: verdana;"&gt;&lt;li&gt;&lt;span style="color: rgb(153, 51, 153);"&gt;Compact and light weight magnet design&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;span style="font-family:verdana;"&gt;The shortest 3T system on the market today at only 173 cm system lengthLight-weight magnet, only 6.3 tons, Zero Helium boil-off, TrueFormTM magnet design offers enhanced image quality&lt;/span&gt;&lt;br /&gt;&lt;ul  style="font-family:verdana;"&gt;&lt;li&gt;&lt;span style="font-weight: bold; color: rgb(153, 51, 153);"&gt;Workflow Automation&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;a style="font-family: verdana;" onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://bp2.blogger.com/_-px19S2_2wM/SBzPxvVaC6I/AAAAAAAAACI/tWT8H9eZ_6s/s1600-h/MRI+MAGNETOM+VERIO+3T.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer;" src="http://bp2.blogger.com/_-px19S2_2wM/SBzPxvVaC6I/AAAAAAAAACI/tWT8H9eZ_6s/s400/MRI+MAGNETOM+VERIO+3T.jpg" alt="" id="BLOGGER_PHOTO_ID_5196256523505503138" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-family:verdana;"&gt;Examples are:&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:verdana;"&gt;Phoenix and PhoenixZIP, AutoAlign, Inline Technology&lt;/span&gt;&lt;br /&gt;&lt;ul  style="font-family:verdana;"&gt;&lt;li&gt;&lt;span style="color: rgb(153, 51, 153); font-weight: bold;"&gt;Computer&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;span style="font-family:verdana;"&gt;Syngo speaking user interface.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:verdana;"&gt;Syngo is the common software platform for all imaging modalities. Enhanced productivity with minimized user interactions per operation step. Based on a powerful Pentium 4 / approx. 3 GHz Panoramic Recon Image Processor reconstructing up to 8694 images per second (256 x 256, 25% recFoV) in combination with a Pentium 4 based Host Computer with two CPU's / approx. 3 GHz and 4 GB RAM capacity.&lt;/span&gt;&lt;br /&gt;&lt;ul  style="font-family:verdana;"&gt;&lt;li&gt;&lt;span style="color: rgb(153, 51, 153); font-weight: bold;"&gt;Cost Effective Siting&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;span style="font-family:verdana;"&gt;33 m2 floor space only, similar to a 1.5T system, No computer room required, Just two electronic cabinets (water-cooled) that can conveniently be placed against the wall&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;a style="font-family: verdana;" onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://bp3.blogger.com/_-px19S2_2wM/SBzUu_VaC7I/AAAAAAAAACQ/WU9YRgTItAQ/s1600-h/MRI+MAGNETOM+VERIO+3T.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer;" src="http://bp3.blogger.com/_-px19S2_2wM/SBzUu_VaC7I/AAAAAAAAACQ/WU9YRgTItAQ/s400/MRI+MAGNETOM+VERIO+3T.jpg" alt="" id="BLOGGER_PHOTO_ID_5196261973819001778" border="0" /&gt;&lt;/a&gt;&lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5516642498532545789-2792233684798411094?l=mri-machine.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://mri-machine.blogspot.com/feeds/2792233684798411094/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5516642498532545789&amp;postID=2792233684798411094' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5516642498532545789/posts/default/2792233684798411094'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5516642498532545789/posts/default/2792233684798411094'/><link rel='alternate' type='text/html' href='http://mri-machine.blogspot.com/2008/05/magnetic-resonance-imaging-mri-is.html' title='M R I (Magnetic Resonance Imaging) : MAGNETOM Verio 3T'/><author><name>faku</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://bp3.blogger.com/_-px19S2_2wM/SBzPg_VaC4I/AAAAAAAAAB4/NXf9wXblE8s/s72-c/MRI+MAGNETUM+VERIO+T3.jpg' height='72' width='72'/><thr:total>0</thr:total></entry></feed>
